Basic knowledge of vacuum pump

Vacuum:Refers to the rarefied gas state in a given space where the pressure is lower than the local atmospheric pressure

Vacuum degree:The rarefaction of gas in a vacuum state can be expressed by negative pressure or absolute pressure. Commonly used units are: Torr, Pa, mbar

Ultimate vacuum:It refers to the maximum vacuum degree that the vacuum pump can reach. The vacuum limit is marked on the nameplate of the vacuum pump.

Effective vacuum:Refers to the actual vacuum degree of the customer during the production process, also known as the operating vacuum. When selecting a vacuum pump, the effective vacuum should be two orders of magnitude lower than the limit vacuum.

Evacuation rate:Under certain pressure and temperature, the gas extracted from the pump inlet per unit time is called the pumping rate, abbreviated as pumping speed. The pumping speed is divided into intake pumping speed and standard pumping speed. The intake pumping speed is marked on the nameplate, unit: m3/h, L/s, m3/min

Conductance:Indicates the ability of a vacuum pipe to pass gas. Under stable conditions, the pipe conductance is equal to the pipe flow divided by the pressure difference between the two ends of the pipe. The unit is: (L/s)

Leakage rate:The vacuum system leak rate refers to the flow rate of a specific gas through the leak hole under specified conditions, unit: Pa·L/s

Vacuum pump unit conversion

Absolute pressure (mbar)

Vacuum (Torr)Vacuum (HgV)Absolute pressure (PsiA)Vacuum (kPa)
10137600.0014.700
8006006.2911.61-21
50037515.157.25-51
30022521.064.35-71
20015024.012.90-81
16012025.202.32-85
1007526.971.45-91
604528.150.87-95
403028.740.58-97
201529.330.29-99
10829.630.15-100
7129.890.01-101

*Pumping speed calculation: Q = V/t*ln(P1/P2)

Q: Pumping speed or actual volume flow, unit: m/min

V: Volume of vacuum chamber or vacuum system, unit: m

t: Time required to evacuate to target vacuum, unit: min

P1: Pressure at the start of evacuation, in absolute unit: mbarA

P2: Target pressure (target vacuum) to be reached by evacuation, in absolute unit: mbarA

JNP Technical Parameter

Machine modelMotor power (KW)Nominal pumping speed (m/min)Ultimate pressure (mbar)Weight (kg)
JNP8-77.57.10.5580
JNP11-10119.80.5600
JNP15-141513.60.5700
JNP18-1718.517.20.5750
JNP22-212221.30.51150
JNP30-293028.80.51300
JNP37-353735.40.51460
JNP45-424541.30.52230
JNP55-565556.70.52370

Installation Dimensions

Machine ModelLWHAA1A2BB1B2
JNP8-7121510151410DN100300421DN65425180
JNP11-10121510151410DN100300421DN65425180
JNP15-14131512651700DN125339413DN80469223
JNP18-17131512651700DN125339413DN80469223
JNP22-21166516151890DN150410600DN100773383
JNP30-29166516151890DN150410600DN100773383
JNP37-35166516151890DN150410600DN100773383
JNP45-42241516152165DN2004081828DN1501268399
JNP55-56241516152165DN2004081828DN1501268399

JNP Series Features

■Full range of built-in inverters

■Independent patented air supply design

■Independent patented air intake valve design, using differential pressure oil supply lubrication

■Vacuum pump is suitable for operation in the pressure range of 5-350mbar

■Applied in lithium batteries, CNC processing, food packaging, chemicals, medicine, aviation simulation and other fields

Get A Free Quote